Descripción
Itech IT8400 Cargas Electrónica DC de Alto rendimiento
Itech IT8400 high-performance DC electronic load has two voltage levels, 600V and 1200V. It supports master-slave connection in parallel with power from 6 kW to 600 kW, and is capable of fast double power loading. It has three current readback ranges with a resolution of up to 40uA. Itech IT8400 has faster loop response and current rising and falling speed. It supports up to 8 working modes. It also has dynamic mode, List, OCP, OPP test, automatic test and battery test functions.
Itech IT8400 has built-in CAN, LAN, GPIB, USB, RS232 and analog interfaces, suitable for remote control and system building. In addition, the full protection function makes it well matched with the test of fuel cell, power battery discharge, DC charging pile, BOC, power electronics, solar, automotive high-voltage components, DC-DC, motor and so on.
Features:
- Max.Voltage : 1200V.
- Current range: 1.5A~15,000 A.
- Power extended to 600 kW through master-slave connection in parallel.
- High-precision three current measurement ranges with resolution up to 40uA.
- Fast double power loading capability (<3 s)
- 25kHz fast dynamic mode, current rising and falling time is adjustable.
- Provide 8 working modes: CC, CV, CR, CP, CC+CV, CV+CR,CR+CC, CP+CC.
- 1 kHz continuous sampling rate.
- List programming.
- The battery discharge function is used to test energy storage devices such as batteries and super capacitors.
- CV loop speed is adjustable to match different power supplies.
- 500 kHz voltage and current sampling rate
- Time measurement, OCP/OPP test short circuit simulation, automatic test.
- Soft start and soft shutdown to prevent voltage fluctuations during on/off.
- I-monitor function.
- Full protection: OVP, UVP, OCP, OPP, OTP, current oscillation protection, current limit, power limit, reverse alarm, etc.
- Power-off retention memory function, recording up to 100 groups data.
- Independent control, easy to maintain and install.
- Built-in standard LAN, USB, RS232, GPIB, CAN and analog, IO interface.
- LabVIEW driver and SCPI protocol
Model | Voltage | Current | Power |
---|---|---|---|
IT8406-600-150 | 600V | 150A | 6kW |
IT8406-1200-75 | 1200V | 75A | 6kW |
IT8412-600-300 | 600V | 300A | 12kW |
IT8412-1200-150 | 1200V | 150A | 12kW |
IT818-600-450 | 600V | 450A | 18kW |
IT8418-1200-225 | 1200V | 225A | 18kW |
IT8424-600-600 | 600V | 600A | 24kW |
IT8424-1200-300 | 1200V | 300A | 24kW |
IT8430-600-750 | 600V | 750A | 30kW |
IT8430-1200-375 | 1200V | 375A | 30kW |
IT8436-600-900 | 600V | 900A | 36kW |
IT8436-1200-450 | 1200V | 450A | 36kW |
IT8442-600-1050 | 600V | 1050A | 42kW |
IT8442-1200-525 | 1200V | 525A | 42kW |
IT8448-600-1200 | 600V | 1200A | 48kW |
IT8448-1200-600 | 1200V | 600A | 48kW |
IT8454-600-1350 | 600V | 1350A | 54kW |
IT8454-1200-675 | 1200V | 675A | 54kW |